Lift emergency call device with analogue telephone line interface

EC II FLEX ES
  • Up to 6 telephone numbers
  • Integrated pictograms
  • Automatic programmable daily/weekly test
  • Complies to EN 81.28, EN 81.70 and EN 81.1-2
  • No external controller unit required

ECII FLEX is a handsfree device to be used as a emergency call unit installed inside lifts or other type of applications like cash dispenser, parking house systems and similar. The unit can be connected to a standard telephone line like an extension line of a PABX or directly to a analogue public line. The variable front panels allow different ways how to install the device: behind an existing panel or complete with a stainless steel front panel with or without alarm button and an frame for wall mounting.

With the activation of the emergency call button the first stored number is dialed using DTMF tones. The telephone number can have a length of up to 20 digits. If the called number does not answer the device will drop the line a start to dial the following stored number. Up to six different number can be programmed. After the answer of the call an acknowledgment signal has to be send to the calling unit. If this signal is not received the ECII FLEX will go on with the dial. At the answer the unit will send an identification code using the CPC procedure or a speech message.

The programming of the device is done using a keypad on the back of the unit or remotely using a telephone with DTMF dial pad or a PC with a modem. The unit provides duplex and simplex handsfree speech connections.

EC II FLEX BG
ECII FLEX BG (without plate)
Version for installation behind panel with yellow and green LED

EC II FLEX AP
ECII FLEX (with AP plate)
Version for wall top installation with two pictograms

EC II FLEX ALBU
ECII FLEX (with ALBU plate)
Version for wall top installation with two pictograms and alarm button
EC II FLEX ALBU
ECII FLEX (with WP plate)
for outdoor installations with
pictograms and alarm button

Standard features

  • Connection to a standard analogue telephone line, 2 wires
  • No external power supply needed (with single installation)
  • Two button or contacts can be connected (alarm call, alarm filtering, technical alarm, end-of- alarm function, etc.)
  • Interface for external lift monitoring system (LMS)
  • Integrated reed contact for special functions (i.e. end-of-alarm, technician on side)
  • Up to six 20 digits long telephone numbers can be stored for emergency calls
  • Up to two 20 digits long telephone numbers can be stored for test calls
  • More telephone numbers for info alarm, technical alarm, battery alarm and en-of-alarm can be programmed
  • For each telephone number a different protocol (DTMF, CPC or P100) can be defined
  • Skip to the next stored number if no answer, no acknowledge or busy tone detection
  • Call forward from the answering party using a DTMF code
  • 7 programmable ID codes up to 10 digits long
  • Programmaing using build in keypad, DTMF phone, or PC over modem or USB cable
  • Automatic call answer (programmable)
  • Simplified call answer
  • Programmbale number of calls for automatic answer
  • Highend speakerphone
  • Two recordable speech messages for information in the cabin or identification at the remote side
  • Duplex/simplex switch using DTMF codes
  • Call disconnect using a DTMF code
  • DTMF dial
  • Two coloured LED indicator for status and connection to the EN 81:70, EN 81:28 (2014) requirements
  • Programmable test alarm setup between 1 and 30 days
  • Programmable number of test call between 1 and 20
  • Fast test call (CLIP call)
  • Up to 9 unit connected to one telephone line using an external PSU or DC/DC converter
  • Calling party identification using CPC or P100 protocol
  • Connection to an external loop antenna amplifier
  • Volume control, also during connection
  • Automatic alarm button recognition (closer or opener)
  • Automatic alarm button failure recognition with technical alarm
  • Alarm filtering with contact or external senors
  • Optional driver contact
  • Programmable busy tone detection
  • Programmable alarm button filtering between 1 and 30 seconds

Optional features

  • External driver for pictogram indicator as by EN 81:70
  • External alarm buttons
  • External speakerphone units
  • External PSU with back up battery
  • 12 V and 24 V DC/DC power converter
  • Intercom unit for communication with machine room
  • Gateway for GSM(UMTS/LTE or VoIP (SIP) networks
  • Loop antenna amplifier with 12 or 24 Vdc power supply
  • Machine room intercom unit
  • Pit unit
  • Lift monitoring system

Technical data

  • Power supply: form telephone line with single installation, 12 V od 24 Vdc with multiple installation using one telephone line
  • Power consumption: 25-45 µA (Standby), 12-60 mA (nominal), 4-16 mA (with external power supply)
  • Indicators: one yellow, one green LED with pictograms
  • Test alarm: programmable between 1 and 30 days or none
  • Alarm receiver: Telelarm VIS, Attendo Wilma, Eurofunk, Netcom, Alec, DTMF phones, mobile phones
  • Protocol: CPC, P100
  • Speakerphone: duplex or simplex
  • Dial: DTMF
  • Detectable dial tone: CTR 21 425 Hz continous tone
  • Detectable busy tone: programmable
  • Programming: using keypad on the unit or remote from phone or PC
  • Up to two N/C or N/O alarm buttons connectable
  • Automatic answer with incoming call (programmable)
  • Dimension BG unit (LxWxH): 105 x 90 x 19 mm
  • Weight BG unit: 235 g
  • Dimension AP case (LxWxH): 136 x 126 x 23 mm (incl. frame);Weight: 544 g (with BG unit)
  • Dimension ALBU case (LxWxH): 180 x 126 x 23 mm (incl. frame);Weight: 655 g (with BG unit)
  • Dimension ES plate (LxWxH): 215 x 123 x 4 mm; Weight:1000 Gramm (with BG unit)
  • Dimension WP plate (LxWxH): 215 x 123 x 14 mm: Weight:: 1200 Gramm (with BG unit). Needs for the installation a flush or wall mounting box.
  • Environment: -20° to + 50° C, 90% humidity (not condensing)
  • Security: EN60950-1:2001
  • EMC: EN50801-1, EN12015, EN50082-1, EN120016
  • Telephony: TBR 21
  • Approvals: R&TTE, CE
  • Other applyable norms: EN 81:1-2, EN 81:28 (2014), EN 81:70, TRA106, 1999/5/EG; CTR 21