New
for the download |
PDF
ECII FLEX
quick guide
3 MB |
PDF
ECII FLEX WP
technical datasheet
0,7 MB |
PDF
ECII FLEX
technical datasheet
0,7 MB |
PDF
application note
new alarm button for ALBU
0,2 MB |
ZIP
EC II FLEX
remote programming 1.00
1 ,7 MB |
|
Lift
emergency call device with analogue telephone line interface |
|
|
- Up
to 6 telephone numbers
- Integrated
pictograms
- Automatic
programmable daily/weekly test
- Complies
to EN 81.28, EN 81.70 and EN 81.1-2
- No
external controller unit required
|
ECII
FLEX is a handsfree device to be used as a emergency call unit
installed inside lifts or other type of applications like cash
dispenser, parking house systems and similar. The unit can be
connected to a standard telephone line like an extension line
of a PABX or directly to a analogue public line. The variable
front panels allow different ways how to install the device: behind
an existing panel or complete with a stainless steel front panel
with or without alarm button and an frame for wall mounting.
With
the activation of the emergency call button the first stored number
is dialed using DTMF tones. The telephone number can have a length
of up to 20 digits. If the called number does not answer the device
will drop the line a start to dial the following stored number.
Up to six different number can be programmed. After the answer
of the call an acknowledgment signal has to be send to the calling
unit. If this signal is not received the ECII FLEX will go on
with the dial. At the answer the unit will send an identification
code using the CPC procedure or a speech message.
The
programming of the device is done using a keypad on the back of
the unit or remotely using a telephone with DTMF dial pad or a
PC with a modem. The unit provides duplex and simplex handsfree
speech connections. |
ECII
FLEX BG (without plate)
Version
for installation behind panel with yellow and green LED
|
ECII FLEX (with AP plate)
Version for wall top installation with two pictograms
|
ECII
FLEX (with ALBU plate)
Version for wall top installation with two pictograms and alarm
button |
ECII
FLEX (with WP plate)
for outdoor installations with
pictograms and alarm button |
Standard
features
- Connection
to a standard analogue telephone line, 2 wires
- No
external power supply needed (with single installation)
-
Two button or contacts can be connected (alarm call, alarm filtering,
technical alarm, end-of-
alarm function, etc.)
- Interface
for external lift monitoring system (LMS)
- Integrated
reed contact for special functions (i.e. end-of-alarm, technician
on side)
- Up
to six 20 digits long telephone numbers can be stored for emergency
calls
- Up
to two 20 digits long telephone numbers can be stored for test
calls
- More
telephone numbers for info alarm, technical alarm, battery alarm
and en-of-alarm can be programmed
- For
each telephone number a different protocol (DTMF, CPC or P100)
can be defined
- Skip
to the next stored number if no answer, no acknowledge or busy
tone detection
-
Call forward from the answering party using a DTMF code
- 7
programmable ID codes up to 10 digits long
-
Programmaing using build in keypad, DTMF phone, or PC over modem
or USB cable
- Automatic
call answer (programmable)
- Simplified
call answer
- Programmbale
number of calls for automatic answer
- Highend
speakerphone
- Two
recordable speech messages for information in the cabin or identification
at the remote side
- Duplex/simplex
switch using DTMF codes
-
Call disconnect using a DTMF code
-
DTMF dial
-
Two coloured LED indicator for status and connection to the
EN 81:70, EN 81:28 (2014) requirements
-
Programmable test alarm setup between 1 and 30 days
- Programmable
number of test call between 1 and 20
- Fast
test call (CLIP call)
-
Up to 9 unit connected to one telephone line using an external
PSU or DC/DC converter
-
Calling party identification using CPC or P100 protocol
-
Connection to an external loop antenna amplifier
-
Volume control, also during connection
- Automatic
alarm button recognition (closer or opener)
- Automatic
alarm button failure recognition with technical alarm
- Alarm
filtering with contact or external senors
- Optional
driver contact
- Programmable
busy tone detection
- Programmable
alarm button filtering between 1 and 30 seconds
|
Optional
features
- External
driver for pictogram indicator as by EN 81:70
- External
alarm buttons
- External
speakerphone units
- External
PSU with back up battery
- 12
V and 24 V DC/DC power converter
- Intercom
unit for communication with machine room
-
Gateway for GSM(UMTS/LTE or VoIP (SIP) networks
-
Loop antenna amplifier with 12 or 24 Vdc power supply
-
Machine room intercom unit
-
Pit unit
-
Lift monitoring system
|
Technical
data
- Power
supply: form telephone line with single installation, 12 V od
24 Vdc with multiple installation using one telephone line
- Power
consumption: 25-45 µA (Standby), 12-60 mA (nominal), 4-16 mA
(with external power supply)
-
Indicators: one yellow, one green LED with pictograms
-
Test alarm: programmable between 1 and 30 days or none
-
Alarm receiver: Telelarm VIS, Attendo Wilma, Eurofunk, Netcom,
Alec, DTMF phones, mobile phones
- Protocol:
CPC, P100
-
Speakerphone: duplex or simplex
-
Dial: DTMF
-
Detectable dial tone: CTR 21 425 Hz continous tone
-
Detectable busy tone: programmable
-
Programming: using keypad on the unit or remote from phone or
PC
-
Up to two N/C or N/O alarm buttons connectable
-
Automatic answer with incoming call (programmable)
- Dimension
BG unit (LxWxH): 105 x 90 x 19 mm
-
Weight BG unit: 235 g
-
Dimension AP case (LxWxH): 136 x 126 x 23 mm (incl. frame);Weight:
544 g (with BG unit)
- Dimension
ALBU case (LxWxH): 180 x 126 x 23 mm (incl. frame);Weight: 655
g (with BG unit)
- Dimension
ES plate (LxWxH): 215 x 123 x 4 mm; Weight:1000 Gramm (with
BG unit)
- Dimension
WP plate (LxWxH): 215 x 123 x 14 mm: Weight:: 1200 Gramm (with
BG unit). Needs for the installation a flush or wall mounting
box.
-
Environment: -20° to + 50° C, 90% humidity (not condensing)
-
Security: EN60950-1:2001
-
EMC: EN50801-1, EN12015, EN50082-1, EN120016
-
Telephony: TBR 21
-
Approvals: R&TTE, CE
-
Other applyable norms: EN 81:1-2, EN 81:28 (2014), EN 81:70,
TRA106, 1999/5/EG; CTR 21
|
|